Mdr Classification Rules Guidance

Before medical device manufacturers can legally mark their CE products in Europe, they must comply with the corresponding European Commission directive or regulation on medical devices. It is extremely important to know the correct medical device classification for your product before giving your product the CE marking. Classification affects your device`s regulatory requirements, as well as the approval process and associated costs. The classification of medical devices is based on the following parameters: The EU uses a rules-based system to determine the risk class of a medical device. In Annex VIII of the MDR, you will find 22 rules for the classification of medical devices. The MDR refers to four classifications of medical devices: Europe uses a rules-based classification system for medical devices Annex VIII of the MDR now contains 22 rules. The level of regulatory control and compliance requirements for the MDR increase with the level of risk associated with the finished medical device. The European system contrasts with the American system, which largely depends on the discovery of similar devices (predicates) already approved by the FDA. Would IVDR revise IVD classification rules? Yes. The IVDR will revise the classification system and IVD requirements. IVD companies can also expect notified bodies to be more involved in the regulatory process. To learn more about the regulatory changes for IVDs, download our detailed white paper that describes how classification is done by explaining terms such as „useful life” and „invasiveness”.

After clarifying the meaning of the terms, the guide explains the application of the classification rules, also with a practical example. There are no strict rules that say that a device that is invasive, for example, falls into class IIa. Once you have defined the type of device (invasive, non-invasive, active or special), you must check its other parameters: the longer the useful life or the more „invasive” it is in terms of body part, the higher the risk class (in terms of MDR classification rules). For example, devices that are invasive in relation to body orifices (with the exception of surgical invasive devices) are classified in Class I if they are intended for temporary use, Class IIa if they are intended for short-term use or Class IIb if they are intended for long-term use. Surgical invasive devices intended for short-term use are classified in Class IIa; if they are specifically intended for the control, diagnosis, monitoring or correction of a defect in the heart or central circulatory system, they are classified in Class III. The MDR has some additional special regulations, including for nanomaterials. To learn more about the difference between the classification of medical devices in Europe and the United States, download this free white paper: FDA vs. MDR technical documentation. The risk level of the assigned classification of the medical device determines the conformity assessment route to be followed for that medical device. Will the new Medical Device Regulation (MDR) affect classification rules in Europe? The MDR will revise classification rules and compliance requirements for certain products, such as certain Class II implants and substance-based products. For more information on MDR and IVDR changes, see our white paper. According to the new regulation, it is important to understand the EU MDR classification rules – in particular the classification to which your medical device is subject – and the rules for classifications.

Looking for more information about the next MDR? Access your free MDR compliance toolkit today. In the EU, medical devices are regulated by the European Commission (EC). Already in 2017, the European Commission defined its new regulations for medical devices – the European Union Medical Device Regulation or EU MDR 2017/745. The MDR, as it is commonly known, is the document that covers the classification of medical devices in the EU and replaces the existing Medical Device Directive (MDD). We have offices throughout Europe to assist us with medical device classification or regulatory strategy. Active devices are all devices that require a power source to function. For active devices, classification rules 9 to 13 shall apply: To facilitate classification, Annex 8 contains 22 EU-MDR classification rules. Although there is still no common EU nomenclature for medical devices (Article 26), the rules aim to classify medical devices in their correct classifications.

In addition, the MDR has identified some new technologies, such as nanomaterials, that also require attention. For all these types of devices, the MDR has developed the following classification rules 14 to 22, which cover specific products: Article 51 states that all medical devices must be classified in one of four classes. The classification determines the route of conformity assessment of the product. Although classification is primarily the responsibility of the manufacturer, it affects the notified body if the product falls under classes IIa, IIb or III. Article 51 confirms that, where a manufacturer and a notified body cannot agree on classification, the competent authority of the manufacturer is the body that takes the final decision. As an example of the application of classification rules, MDCG cites a simple wound drainage system consisting of a cannula, a tube and a collector. Since flexible hoses and manifold are not invasive, they are subject to Rule 1 and are classified in Class I. The cannula, on the other hand, is surgically invasive, i.e.

subject to Rule 7 and classified in Class IIa. In this case, the manufacturer could apply Class IIa to the whole product or apply separate conformity assessment procedures for Class I and IIa parts. The MDR divide products into four categories, classes I, IIa, IIb and III, based on their intended purpose and inherent risks. Manufacturers must propose and justify the risk class of their products in their technical documentation. The European Union has already established classification rules in an MDR annex. The MDAG Guidelines expand the Annex to the MDR to help manufacturers follow the rules and understand the implications of their classification. The rules are divided into four sections, and the rules in each section apply to a specific category of devices. With the new Medical Device Regulation, it is important for medical device manufacturers to understand how the new classification rules apply to different types of medical devices. These new EU MDR classification rules can be a bit confusing, and since they affect what you need to do before selling your product, you need to understand them to make sure you don`t delay your time to market with unnecessary work or setbacks.

The first step in the European regulatory process is the classification of the product in accordance with the Medical Device Regulation (MDR) No 2017/745 (for medical devices or active implantable medical devices) or the In Vitro Diagnostic Medical Devices (IVDR) Regulation No 2017/746 (for IVD devices). It should be noted that the MDR also includes devices that are specifically described in Annex XVI and have no medical purpose. Choose the most appropriate rule(s) for your product to determine the risk class of your medical device in the EU. If more than one of the rules apply to a device, the RDM dictates that you must use the strictest rule that results in the highest classification level. Finally, it is important to document the classification decision and supporting rationale. This is another point required in the technical documentation (Annex II, point 1.1): the MDR will contain 22 classification rules, four more than the previous Medical Device Directive (MDD). All rules are based on the potential risks associated with the device, its engineering design and how the device is manufactured. One of the most important steps in placing a medical device on the market in the European Union (EU) is to determine the correct classification of your product. The MDAG devotes much of the remaining guidelines to explaining the 22 MDR classification rules.